Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Quant Imaging Med Surg ; 14(1): 123-135, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38223084

RESUMO

Background: Lung ultrasound (LUS) and diaphragm ultrasound (DUS) are the appropriate modalities for conservative observation to those patients who are with stable pneumothorax, as well as for the timely detection of life-threatening pneumothorax at any location, due to they are portable, real-time, relatively cost effective, and most important, without radiation exposure. The absence of lung sliding on LUS M-mode images and the abnormality of diaphragmatic excursion (DE) on DUS M-mode images are the most common and novel diagnostic criteria for pneumothorax, respectively. However, visual inspection of M-mode images remains subjective and quantitative analysis of LUS and DUS M-mode images are required. Methods: Shannon entropy of LUS M-mode image (ShanEnLM) and DE based on the automated measurement (DEAM) are adapted to the objective pneumothorax diagnoses and the severity quantifications in this study. Mild, moderate, and severe pneumothoraces were induced in 24 male New Zealand rabbits through insufflation of room air (5, 10 and 15, and 25 and 40 mL/kg, respectively) into their pleural cavities. In vivo intercostal LUS and subcostal DUS M-mode images were acquired using a point-of-care system for estimating ShanEnLM and DEAM. Results: ShanEnLM and DEAM as functions of air insufflation volumes exhibited U-shaped curves and were exponentially decreasing, respectively. Either ShanEnLM or DEAM had areas under the receiver operating characteristic curves [95% confidence interval (CI)] of 1.0000 (95% CI: 1.0000-1.0000), 0.9833 (95% CI: 0.9214-1.0000), and 0.9407 (95% CI: 0.8511-1.0000) for differentiating between normal and mild pneumothorax, mild and moderate pneumothoraces, and moderate and severe pneumothoraces, respectively. Conclusions: Our findings imply that the combination of ShanEnLM and DEAM give the promising potential for pneumothorax quantitative diagnosis.

2.
Medicine (Baltimore) ; 102(36): e34981, 2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37682204

RESUMO

Metacarpal neck fracture is one of the most common types of hand fractures; the literature suggests that applying a bone plate on the dorsal side provides higher fixation strength than that provided by other fixation methods. However, bone plate fixation on the dorsal side may result in postoperative tendon adhesion. So far, no studies have investigated the fixation of metacarpal neck fractures on the volar side by using a bone plate. The objective of this study was to investigate the differences in the fixation results between bone plate fixation on the dorsal side and bone plate fixation on the volar side of the metacarpal in the case of a metacarpal neck fracture. A saw blade was used to create a transverse metacarpal neck fracture on 14 artificial metacarpal bone specimens. The specimens were divided into 2 groups depending on the fixation method: a volar locking plate (VLP) group and a dorsal locking plate (DLP) group. All specimens were subjected to a cantilever bending test on a material testing system, and a force-displacement curve was used to measure the yield force and stiffness, which served as an indicator of the fixation ability of the 2 fracture fixation methods. For the experimental results, the Mann-Whitney U test was used to compare the fixation abilities of the 2 fixation methods. In terms of yield force, the DLP group (266.9 ± 68.3 N) scored significantly higher than the VLP group (32.6 ± 2.7 N) (P < .05); expressed in terms of median, the DLP group scored 8.2 times higher than the VLP group. Similarly, in terms of stiffness, the DLP group (69.0 ± 13.4 N/mm, median ± interquartile range) scored significantly higher than the VLP group (12.9 ± 1.4 N/mm) (P < .05); expressed in terms of median, the DLP group scored 5.3 times higher than the VLP group. The fixation strength of volar bone plates is only about one-third of that of dorsal bone plates.


Assuntos
Fraturas Ósseas , Traumatismos da Mão , Ossos Metacarpais , Fraturas da Coluna Vertebral , Humanos , Placas Ósseas , Ossos Metacarpais/cirurgia , Fraturas Ósseas/cirurgia , Pescoço
3.
J Orthop Surg Res ; 17(1): 374, 2022 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-35922799

RESUMO

OBJECTIVE: To investigate differences in the effectiveness of two lag screws, a regular bone plate, and locking bone plate fixation in treating horizontal oblique metacarpal shaft fractures. MATERIALS AND METHODS: Horizontal oblique metacarpal shaft fractures were created in 21 artificial metacarpal bones and fixed using one of the three methods: (1) two lag screws, (2) a regular plate, and (3) a locking plate. All the specimens were subjected to the cantilever bending test performed using a material testing machine to enable recording of the force-displacement data of the specimens before failure. The Kruskal-Wallis test was used to compare failure force and stiffness values among the three fixation methods. RESULTS: The mean failure force of the two lag screw group (78.5 ± 6.6 N, mean + SD) was higher than those of the regular plate group (69.3 ± 17.6 N) and locking plate group (68.2 ± 14.2 N). However, the mean failure force did not significantly differ among the three groups. The mean stiffness value of the two lag screw group (17.8 ± 2.6 N/mm) was lower than those of the regular plate group (20.2 ± 10.5 N/mm) and locking plate group (21.8 ± 3.8 N/mm). However, the mean stiffness value did not significantly differ among the three groups. CONCLUSION: The fixation strength of two lag screw fixation did not significantly differ from that of regular and locking bone plate fixation, as indicated by the measurement of the ability to sustain force and stiffness.


Assuntos
Fraturas Ósseas , Traumatismos da Mão , Ossos Metacarpais , Fenômenos Biomecânicos , Placas Ósseas , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Humanos , Ossos Metacarpais/lesões , Ossos Metacarpais/cirurgia
4.
J Orthop Surg Res ; 17(1): 72, 2022 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-35123532

RESUMO

BACKGROUND: For oblique metacarpal shaft fracture, if anatomical reduction is achieved through conservative cast immobilization rather than stable fixation, bone malrotation can easily occur, resulting in severe loss in hand prehensile function. However, whether bone plate fixation or only lag screw fixation is more preferable remains unclear. Few studies have evaluated whether screw fixation can provide biomechanical fixation strength similar to bone plate fixation. OBJECTIVE: We assessed the difference in fixation strength between fixtation with two lag screws and bone plate for oblique metacarpal shaft fractures. MATERIALS AND METHODS: We created oblique metacarpal shaft fractures on 21 artificial bones and fixated them using (1) double lag screw (2LS group), (2) regular plate (RP group), or (3) locked plate (LP group). To obtain the force-displacement data, a cantilever bending test was conducted for each specimen through a material testing machine. One-way analysis of variance and a Tukey test were conducted to compare the maximum fracture force and stiffness of the three fixation methods. RESULTS: The maximum fracture force of the 2LS group (mean + SD: 153.6 ± 26.5 N) was significantly lower than that of the RP (211.6 ± 18.5 N) and LP (227.5 ± 10.0 N) groups (p < 0.001). However, no significant differences were discovered between the RP and LP groups. The coefficient of variation for the maximum fracture force of the 2LS group (17.3%) was more than twice as high as that of the RP (8.7%) and LP (4.4%) groups. In addition, the stiffness of the three fixation methods was similar. CONCLUSION: Compared with bone plate fixation, double lag screw fixation yielded slightly lower maximum bearable fracture force but similar stiffness. Therefore, this technique could be used for treating oblique metacarpal shaft fractures. However, using double lag screw fixation alone is technically demanding and requires considerable surgical experiences to produce consistent results.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Traumatismos da Mão , Ossos Metacarpais/cirurgia , Fenômenos Biomecânicos , Fraturas Ósseas/diagnóstico por imagem , Humanos , Ossos Metacarpais/diagnóstico por imagem , Ossos Metacarpais/lesões
5.
J Ultrasound Med ; 41(7): 1699-1711, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34698398

RESUMO

OBJECTIVE: Lung ultrasound (LUS) is a radiation-free, affordable, and bedside monitoring method that can detect changes in pulmonary aeration before hypoxic damage. However, visual scoring methods of LUS only enable subjective diagnosis. Therefore, quantitative analysis of LUS is necessary for obtaining objective information on pulmonary aeration. Because raw data are not always available in conventional ultrasound systems, Shannon entropy (ShanEn) of information theory without the requirement of raw data is valuable. In this study, we explored the feasibility of ShanEn estimated through grayscale histogram (GSH) analysis of LUS images for the quantification of pulmonary aeration. METHODS: Different degrees of pulmonary aeration caused by edema was induced in 32 male New Zealand rabbits intravenously injected with 0.1 mL/kg saline (the control group) and 0.025, 0.05, and 0.1 mL/kg oleic acid (mild, moderate, and severe groups, respectively). In vivo grayscale LUS images were acquired using a commercial point-of-care ultrasound system for estimation of GSH and corresponding ShanEn. Both lungs of each rabbit were dissected, weighed, and dried to determine the wet weight-to-dry weight ratio (W/D) through gravimetry. RESULTS: The determination coefficients of linear correlations between ShanEn and W/D increased from 0.0487 to 0.7477 with gain and dynamic range (DR). In contrast to visual scoring methods of pulmonary aeration that use median gain and low DR, ShanEn for quantifying pulmonary aeration requires high gain and DR. CONCLUSION: The current findings indicate that ShanEn estimated through GSH analysis of LUS images acquired using conventional ultrasonic imaging systems has great potential to provide objective information on pulmonary aeration.


Assuntos
Pulmão , Sistemas Automatizados de Assistência Junto ao Leito , Animais , Humanos , Pulmão/diagnóstico por imagem , Masculino , Testes Imediatos , Coelhos , Tórax , Ultrassonografia/métodos
6.
Medicine (Baltimore) ; 100(39): e27375, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34596154

RESUMO

ABSTRACT: Metacarpal shaft fractures are common hand fractures. Although bone plates possess strong fixation ability, they have several limitations. The use of headless compression screws for fracture repair has been reported, but their fixation ability has not been understood clearly.This study aimed to compare the fixation ability of locked plate with that of headless compression screw for metacarpal fracture repair.A total of 14 artificial metacarpal bones (Sawbones, Vashon, WA, USA) were subjected to transverse metacarpal shaft fractures and divided into 2 groups. The first group of bones was fixed using locked plates (LP group), whereas the second group was fixed using headless compression screws (HC group). A material testing machine was used to perform cantilever bending tests, whereby maximum fracture force and stiffness were measured. The fixation methods were compared by conducting a Mann-Whitney U test.The maximum fracture force of the HC group (285.6 ±â€Š57.3 N, median + interquartile range) was significantly higher than that of the LP group (227.8 ±â€Š37.5 N; P < .05). The median of the HC group was 25.4% greater. However, no significant difference in stiffness (P > .05) was observed between the HC (65.2 ±â€Š24.6 N/mm) and LP (61.7 ±â€Š19.7 N/mm) groups.Headless compression screws exhibited greater fixability than did locked plates, particularly in its resistance to maximum fracture force.


Assuntos
Placas Ósseas/normas , Parafusos Ósseos/normas , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Ossos Metacarpais/lesões , Humanos , Teste de Materiais/métodos , Modelos Anatômicos
7.
J Orthop Surg Res ; 16(1): 441, 2021 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-34233702

RESUMO

BACKGROUND: Metacarpal shaft fractures are a common hand trauma. The current surgical fixation options for such fractures include percutaneous Kirschner wire pinning and nonlocking and locking plate fixation. Although bone plate fixation, compared with Kirschner wire pinning, has superior fixation ability, a consensus has not been reached on whether the bone plate is better placed on the dorsal or lateral side. OBJECTIVE: The purpose of this study was to evaluate the fixation of locking and regular bone plates on the dorsal and lateral sides of a metacarpal shaft fracture. MATERIALS AND METHODS: Thirty-five artificial metacarpal bones were used in the experiment. Metacarpal shaft fractures were created using a saw blade, which were then treated with four types of fixation as follows: (1) a locking plate with four locking bicortical screws on the dorsal side (LP_D); (2) a locking plate with four locking bicortical screws on the lateral side (LP_L); (3) a regular plate with four regular bicortical screws on the dorsal side (RP_D); (4) a regular plate with four regular bicortical screws on the lateral side (RP_D); and (5) two K-wires (KWs). All specimens were tested through cantilever bending tests on a material testing system. The maximum fracture force and stiffness of the five fixation types were determined based on the force-displacement data. The maximum fracture force and stiffness of the specimens with metacarpal shaft fractures were first analyzed using one-way analysis of variance and Tukey's test. RESULTS: The maximum fracture force results of the five types of metacarpal shaft fracture were as follows: LP_D group (230.1 ± 22.8 N, mean ± SD) ≅ RP_D group (228.2 ± 13.4 N) > KW group (94.0 ± 17.4 N) > LP_L group (59.0 ± 7.9 N) ≅ RP_L group (44.5 ± 3.4 N). In addition, the stiffness results of the five types of metacarpal shaft fracture were as follows: LP_D group (68.7 ± 14.0 N/mm) > RP_D group (54.9 ± 3.2 N/mm) > KW group (20.7 ± 5.8 N/mm) ≅ LP_L group (10.6 ± 1.7 N/mm) ≅ RP_L group (9.4 ± 1.2 N/mm). CONCLUSION: According to our results, the mechanical strength offered by lateral plate fixation of a metacarpal shaft fracture is so low that even KW fixation can offer relatively superior mechanical strength; this is regardless of whether a locking or nonlocking plate is used for lateral plate fixation. Such fixation can reduce the probability of extensor tendon adhesion. Nevertheless, our results indicated that when lateral plate fixation is used for fixating a metacarpal shaft fracture in a clinical setting, whether the mechanical strength offered by such fixation would be strong enough to support bone union remains questionable.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Ossos Metacarpais/lesões , Ossos Metacarpais/cirurgia , Fenômenos Biomecânicos , Humanos , Teste de Materiais
8.
BMC Musculoskelet Disord ; 22(1): 431, 2021 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-33971840

RESUMO

BACKGROUND: Metacarpal shaft fractures are a common type of hand fracture. Despite providing strong fixation strength, plate fixation has numerous shortcomings. Concerning internal fixation with Kirschner wires (K-wires), although this approach is frequently used to treat metacarpal shaft fractures, the lack of functional stability may result in fixation failure. OBJECTIVE: To evaluate the effect of figure-of-eight cerclage wire on fixation for transverse metacarpal shaft fractures using two K-wires. MATERIALS AND METHODS: We used a saw blade to create transverse metacarpal shaft fractures in 14 fourth-generation artificial third metacarpal bones (Sawbones, Vashon, WA, USA), which were assigned to groups undergoing fixation with two K-wires (KP) or with two K-wires and figure-of-eight cerclage wire (KP&F8). All specimens were subjected to material testing, specifically cantilever bending tests. The maximum fracture force and stiffness of the two fixation types were determined on the basis of the force-displacement data. The Mann-Whitney U test was used to compare between-group differences in maximum fracture force and stiffness. RESULTS: The maximum fracture force of the KP group (median ± interquartile range = 97.30 ± 29.70 N) was significantly lower than that of the KP&F8 group (153.2 ± 69.50 N, p < 0.05; Figure 5a), with the median of the KP&F8 group exceeding that of the KP group by 57.5%. Similarly, stiffness was significantly lower in the KP group (18.14 ± 9.84 N/mm) than in the KP&F8 group (38.25 ± 23.49 N/mm; p < 0.05; Figure 5b), with the median of the KP&F8 group exceeding that of the KP group by 110.9%. CONCLUSION: The incorporation of a figure-of-eight cerclage wire increased the maximum fracture force and stiffness by 57.5 and 110.9%, respectively, compared with those achieved in standard two K-wire fixation. Therefore, hand surgeons are advised to consider the proposed approach to increase fixation strength.


Assuntos
Fraturas Ósseas , Ossos Metacarpais , Placas Ósseas , Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Humanos , Ossos Metacarpais/diagnóstico por imagem , Ossos Metacarpais/cirurgia
9.
BMC Musculoskelet Disord ; 22(1): 146, 2021 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-33546670

RESUMO

BACKGROUND: Metacarpal shaft fracture is a common fracture in hand trauma injuries. Surgical intervention is indicated when fractures are unstable or involve considerable displacement. Current fixation options include Kirschner wire, bone plates, and intramedullary headless screws. Common complications include joint stiffness, tendon irritation, implant loosening, and cartilage damage. OBJECTIVE: We propose a modified fixation approach using headless compression screws to treat transverse or short-oblique metacarpal shaft fracture. MATERIALS AND METHODS: We used a saw blade to model transverse metacarpal neck fractures in 28 fresh porcine metacarpals, which were then treated with the following four fixation methods: (1) locked plate with five locked bicortical screws (LP group), (2) regular plate with five bicortical screws (RP group), (3) two Kirschner wires (K group), and (4) a headless compression screw (HC group). In the HC group, we proposed a novel fixation model in which the screw trajectory was oblique to the long axis of the metacarpal bone. The entry point of the screw was in the dorsum of the metacarpal neck, and the exit point was in the volar cortex of the supracondylar region; thus, the screw did not damage the articular cartilage. The specimens were tested using a modified three-point bending test on a material testing system. The maximum fracture forces and stiffness values of the four fixation types were determined by observing the force-displacement curves. Finally, the Kruskal-Wallis test was adopted to process the data, and the exact Wilcoxon rank sum test with Bonferroni adjustment was performed to conduct paired comparisons among the groups. RESULTS: The maximum fracture forces (median ± interquartile range [IQR]) of the LP, RP, HC, and K groups were 173.0 ± 81.0, 156.0 ± 117.9, 60.4 ± 21.0, and 51.8 ± 60.7 N, respectively. In addition, the stiffness values (median ± IQR) of the LP, HC, RP, and K groups were 29.6 ± 3.0, 23.1 ± 5.2, 22.6 ± 2.8, and 14.7 ± 5.6 N/mm, respectively. CONCLUSION: Headless compression screw fixation provides fixation strength similar to locked and regular plates for the fixation of metacarpal shaft fractures. The headless screw was inserted obliquely to the long axis of the metacarpal bone. The entry point of the screw was in the dorsum of the metacarpal neck, and the exit point was in the volar cortex of the supracondylar region; therefore the articular cartilage iatrogenic injury can be avoidable. This modified fixation method may prevent tendon irritation and joint cartilage violation caused by plating and intramedullary headless screw fixation.


Assuntos
Fraturas Ósseas , Ossos Metacarpais , Animais , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Ossos Metacarpais/diagnóstico por imagem , Ossos Metacarpais/cirurgia , Suínos
10.
Artigo em Inglês | MEDLINE | ID: mdl-33013696

RESUMO

Calcitonin is a small peptide hormone secreted from the parafollicular cells of the thyroid gland in response to an increase in serum calcium. The inhibition of osteoclastic resorption is the main mechanism by which calcitonin quickly decreases circulating calcium levels. Although calcitonin pharmacologically acts on osteoclasts to prevent bone resorption, the results of studies on genetically modified animals have shown that the physiological effect of calcitonin is in the inhibition of osteoblastic bone formation. Because the calcitonin receptor is only expressed in osteoclasts, the effect of calcitonin on osteoblasts maybe indirect and mediated via osteoclasts. Wnt ligands are involved in various aspects of skeletal biology, including bone remodeling and endochondral bone formation. Wnt10b has recently been recognized as a clastokine, and is potentially a therapeutic target for treating bone disorders. However, the extent to which Wnt signaling is involved in bone physiology and disease is not yet fully understood. We hypothesize that calcitonin indirectly increases osteoblastic bone formation by inducing Wnt10b expression in osteoclasts. Micro-CT analysis revealed reduced bone loss in calcitonin-treated ovariectomized rats. The serum of animals treated with calcitonin had decreased TRAP5b and CTX-1 but increased osteocalcin, P1NP, and Wnt10b. Immunohistochemistry staining showed that the level of Wnt10b in the femur was increased in calcitonin-treated groups as compared with control groups. Hematopoietic mononuclear cells were separated from rat femur and tibia bone marrow, and were induced into osteoclasts following treatment with M-CSF and RANKL. In these cells, immunoconfocal microscopy and Western blot analysis showed that calcitonin induced an increase in Wnt10b expression. In a culture of osteoblasts isolated from neonatal rat calvariae, the calcitonin-treated osteoclast supernatant showed an increase in mineralization, as indicated by ALP and alizarin red staining. Taken together, these results indicate that calcitonin induces bone formation by increasing the expression of Wnt10b in osteoclasts in ovariectomy-induced osteoporotic rats. The present study provides in-depth information about the effects of calcitonin on bone remodeling and will thus help in the development of future potential therapeutic strategies for postmenopausal osteoporosis.


Assuntos
Conservadores da Densidade Óssea/farmacologia , Calcitonina/farmacologia , Fêmur/efeitos dos fármacos , Osteoclastos/efeitos dos fármacos , Osteogênese/efeitos dos fármacos , Osteoporose/tratamento farmacológico , Osteoporose/metabolismo , Proteínas Wnt/metabolismo , Animais , Densidade Óssea/efeitos dos fármacos , Conservadores da Densidade Óssea/uso terapêutico , Remodelação Óssea/efeitos dos fármacos , Calcitonina/uso terapêutico , Feminino , Fêmur/diagnóstico por imagem , Fêmur/metabolismo , Osteoclastos/metabolismo , Osteoporose/diagnóstico por imagem , Osteoporose/etiologia , Ovariectomia/efeitos adversos , Ratos , Ratos Sprague-Dawley , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...